Start with an in-range parcel and a readable label. Follow it from induction to its assigned chute. Introduce one exception at a time to see whether a deviation starts at identification, induction or collection.
Change one condition per run. Use an in-range parcel with an unreadable label to test no-read handling. Use an out-of-range parcel with a readable label to check rejection before induction. To test chute unavailability, use an in-range parcel with a readable label and make its assigned chute unavailable as agreed.
Give each sample a test ID independent of its shipping label. Record the condition, expected action and final destination. Check the agreed response, such as an exception chute, recirculation or a feed pause for manual handling. Track recirculated parcels to their final destination.
Record where the exception was detected, what the equipment or operator did and where the parcel ended up. After the chute is available again or manual handling is complete, check that the first normal parcel reaches its assigned chute.
Pass a case only if both the action and final destination match the agreed result. For any deviation, record where it occurred, what you observed and the conditions needed to repeat the test.